Page 109 - 《中国医疗器械杂志》2026年第2期
P. 109
Chinese Journal of Medical Instrumentation 2026年 第50卷 第2期
监 管 与 测 试
代方法的研究与验证,提前谋划布局,实现与国际 for skin sensitization testing[J]. Toxicol In Vitro 2015,
先进方法的接轨,保障我国医疗器械安全和人民群 30(1 Pt B): 373-382.
众的健康。 [13] PIROIRD C, OVIGNE J M, ROUSSET F, et al. The
Myeloid U937 Skin Sensitization Test (U-SENS)
addresses the activation of dendritic cell event in the
参考文献
adverse outcome pathway for skin sensitization[J].
[1] 全国医疗器械生物学评价标准化技术委员会. 医疗器械
Toxicol In Vitro, 2015, 29(5): 901-916.
生物学评价第10部分: 皮肤致敏试验: GB/T 16886.10—
[14] KIMURA Y, FUJIMURA C, ITO Y, et al. Optimization
2024[S]. 北京: 中国标准出版社, 2024.
of the IL-8 Luc assay as an in vitro test for skin
[2] Biological evaluation of medical devices—Part 10: Tests
sensitization[J]. Toxicol In Vitro, 2015, 29(7): 1816-1830.
for skin sensitization: ISO10993-10: 2021[EB/OL].
[15] URBISCH D, MEHLING A, GUTH K, et al. Assessing
(2021-11-16) [2025-05-21]. https://www.iso.org/obp/ui/
skin sensitization hazard in mice and men using non-
en/#iso:std:iso:10993:-10:ed-4:v1:en.
animal test methods[J]. Regul Toxicol Pharmacol, 2015,
[3] GERBERICK G F, VASSALLO J D, BAILEY R E, et al.
71(2): 337-351.
Development of a peptide reactivity assay for screening
[16] EURL ECVAM, Recommendation on the
contact allergenss[J]. Toxicol Sci, 2004, 81(2): 332-343.
KeratinoSens™ assay for skin sensitisation testing
[4] OECD. Test No. 442C: In Chemico Skin Sensitisation:
[EB/OL]. (2015-01-20) [2025-05-21]. https://ihcp.jrc.ec.
Assays addressing the Adverse Outcome Pathway key
europa.eu/our_labs/eurl-ecvam/eurl-ecvam-recommendations/
event on covalent binding to proteins, OECD Guidelines
recommendation-keratinosens-skin-sensitisation.
for the Testing of Chemicals, Section 4[EB/OL]. (2019-
[17] EURL ECVAM, The LuSens test method Validation
06-25) [2025-05-21]. https://doi.org/10.1787/9789264229
Study Report[EB/OL]. (2018-06-16) [2025-05-21]. https://
709-en.
[5] FABIAN E, VOGEL D, BLATZ V, et al. Xenobiotic tsar.jrc.ec.europa.eu/test-method/tm2011-10.
[18] EURL ECVAM, Re-analysis of the within and between
metabolizin enzyme activities in cells used for testing
laboratory reproducibility of the human Cell Line
skin sensitization in vitro[J]. Arch Toxicol, 2013, 87(9):
Activation Test (h-CLAT[EB/OL]. (2015-02-25) [2025-
1683-1696.
05-21]. https://eurl-ecvam.jrc.ec.europa.eu/eurl-ecvam-
[6] OECD. Test No. 442D: In Vitro Skin Sensitisation: ARE-
Nrf2 Luciferase Test Method. OECD Guidelines for the recommendations/eurl-ecvam-recommendation-on-the-
Testing of Chemicals, Section 4[EB/OL]. (2018-06-25) human-cell-line-activation-test-h-clat-for-skin-sensitisation-
[2025-05-21]. https://doi.org/10.1787/9789264229822-en. testing.
[7] THORNE N, INGLESE J, AULD D S. Illuminating [19] EURL ECVAM, The U-SENS™ test method Validation
insights into firefly luciferase and other bioluminescent Study Report[EB/OL]. (2017-07-07) [2025-05-21]. https://
reporters used in chemical biology[J]. Chem Biol, 2010, ihcp.jrc.ec.europa.eu/our_labs/eurl-ecvam/eurl-ecvam-
17(6): 646-657. recommendations.
[8] RAMIREZ T, MEHLING A, KOLLE S N, et al. LuSens: [20] OECD, Report of the Peer Review Panel for the IL-8
a keratinocyte based ARE reporter gene assay for use in Luciferase (IL-8 Luc) Assay for in vitro skin sensitisation.
integrated testing strategies for skin sensitization hazard [EB/OL]. (2017-11-16) [2025-05-21]. http://www.oecd.
identification[J]. Toxicol In Vitro, 2014, 28(8): 1482- org/env/ehs/testing/series-testing-assessment-publications-
1497. number.htm.
[9] RAMIREZ T, STEIN N, AUMANN A, et al. Intra- and [21] MCKIM J M Jr, KELLER D J Ⅲ, Gorski J R. A new in
inter-laboratory reproducibility and accuracy of the vitro method for identifying chemical sensitizers
LuSens assay: A reporter gene-cell line to detect combining peptide binding with ARE/EpRE-mediated
keratinocyte activation by skin sensitizers[J]. Toxicol In gene expression in human skin cells[J]. Cutan Ocul
Vitro, 2016, 32: 278-286. Toxicol, 2010, 29(3): 171-192.
[10] ASHIKAGA T, YOSHIDA Y, HIROTA M, et al. [22] MCKIM J M Jr, KELLER D J Ⅲ, GORSKI J R. An in
Development of an in vitro skin sensitization test using vitro method for detecting chemical sensitization using
human cell lines: The human Cell Line Activation Test human reconstructed skin models and its applicability to
(h-CLAT) I. Optimization of the h-CLAT protocol[J]. cosmetic, pharmaceutical, and medical device safety
Toxicol In Vitro, 2006, 20(5): 767-773. testing[J]. Cutan Ocul Toxicol, 2012, 31(4): 292-305.
[11] TAKENOUCHI O, MIYAZAWA M, SAITO K, et al. [23] COTTREZ F, BOITEL E, AURIAULT C, et al. Genes
Predictive performance of the human Cell Line Activation specifically modulated in sensitized skins allow the
Test (h-CLAT) for lipophilic with high octanolwater detection of sensitizers in a reconstructed human skin
partition coefficients[J]. Toxicol, 2013, 38: 599-609. model. Development of the SENS-IS assay.[J]. Toxicol In
[12] ALÉPÉE N, PIROIRD C, AUJOULAT M, et al. Vitro, 2015, 29(4): 787-802.
Prospective multicentre study of the U-SENS test method [24] COTTREZ F, BOITEL E, PELLEVOISIN C, et al.
223