Page 161 - 《爆炸与冲击》2025年第9期
P. 161

第 45 卷                吴    昊,等: CFRP布加固砌体填充墙抗爆分析与设计                             第 9 期

               [2]   中华人民共和国住房和城乡建设部. 纤维增强复合材料工程应用技术标准: GB 50608—2020 [S]. 北京: 中国计划出版
                    社, 2020.
                    Ministry of Housing and Urban Rural Development of the People᾿s Republic of China. Technical standard for fiber reinforced
                    polymer (FRP) in construction: GB 50608—2020 [S]. Beijing: China Planning Press, 2020.
               [3]   ACI  440  Committee.  ACI  440.2R-08  guide  for  the  design  and  construction  of  externally  bonded  FRP  systems  for
                    strengthening concrete structures [S]. Farmington Hills, MI: American Concrete Institute, 2008.
               [4]   ORTON  S  L,  CHIARITO  V  P,  MINOR  J  K,  et  al.  Experimental  testing  of  CFRP-strengthened  reinforced  concrete  slab
                    elements loaded by close-in blast [J]. Journal of Structural Engineering, 2014, 140(2): 04013060. DOI: 10.1061/(ASCE)ST.
                    1943-541X.0000821.
               [5]   SHI Y C, XIONG W, LI Z X, et al. Experimental studies on the local damage and fragments of unreinforced masonry walls
                    under close-in explosions [J]. International Journal of Impact Engineering, 2016, 90: 122–131. DOI: 10.1016/j.ijimpeng.2015.
                    12.002.
               [6]   MUSZYNSKI  L  C,  PURCELL  M  R.  Use  of  composite  reinforcement  to  strengthen  concrete  and  air-entrained  concrete
                    masonry walls against air blast [J]. Journal of Composites for Construction, 2003, 7(2): 98–108. DOI: 10.1061/(ASCE)1090-
                    0268(2003)7:2(98).
               [7]   CHEN L, FANG Q, FAN J Y, et al. Responses of masonry infill walls retrofitted with CFRP, steel wire mesh and laminated
                    bars to blast loadings [J]. Advances in Structural Engineering, 2014, 17(6): 817–836. DOI: 10.1260/1369-4332.17.6.817.
               [8]   万军. 碳纤维布加固砌体填充墙抗近距离小当量炸药爆炸实验研究 [J]. 工程力学, 2019, 36(S1): 293–297. DOI: 10.
                    6052/j.issn.1000-4750.2018.04.S062.
                    WAN  J.  Blast  response  of  CFRP-reinforced  concrete  masonry  wall  against  small  stand-off  distance  explosive  charge  [J].
                    Engineering Mechanics, 2019, 36(S1): 293–297. DOI: 10.6052/j.issn.1000-4750.2018.04.S062.
               [9]   LI Z, CHEN L, FANG Q, et al. Experimental and numerical study on CFRP strip strengthened clay brick masonry walls
                    subjected  to  vented  gas  explosions  [J].  International  Journal  of  Impact  Engineering,  2019,  129:  66–79.  DOI:  10.1016/j.
                    ijimpeng.2019.02.013.
               [10]   TAN  K  H,  PATOARY  M  K  H.  Blast  resistance  of  FRP-strengthened  masonry  walls.Ⅰ:  approximate  analysis  and  field
                    explosion tests [J]. Journal of Composites for Construction, 2009, 13(5): 422–430. DOI: 10.1061/(ASCE)1090-0268(2009)
                    13:5(422).
               [11]   胡嘉辉, 吴昊, 方秦. 近区爆炸作用下砌体填充墙损伤破坏与动态响应的数值模拟 [J]. 振动与冲击, 2021, 40(9): 1–11.
                    DOI: 10.13465/j.cnki.jvs.2021.09.001.
                    HU J H, WU H, FANG Q, et al. Numerical simulation of damage and dynamic response of masonry infilled wall under near
                    zone explosion [J]. Journal of Vibration and Shock, 2021, 40(9): 1–11. DOI: 10.13465/j.cnki.jvs.2021.09.001.
               [12]   CHEN  D,  WU  H,  FANG  Q.  Simplified  micro-model  for  brick  masonry  walls  under  out-of-plane  quasi-static  and  blast
                    loadings [J]. International Journal of Impact Engineering, 2023, 174: 104529. DOI: 10.1016/j.ijimpeng.2023.104529.
               [13]   HAO H, WU C Q. Numerical simulation of damage of low-rise RC frame structures with infilled masonry walls to explosive
                    loads [J]. Australian Journal of Structural Engineering, 2006, 7(1): 13–22. DOI: 10.1080/13287982.2006.11464960.
               [14]   ALSAYED S H, ELSANADEDY H M, AL-ZAHERI Z M, et al. Blast response of GFRP-strengthened infill masonry walls [J].
                    Construction and Building Materials, 2016, 115: 438–451. DOI: 10.1016/j.conbuildmat.2016.04.053.
               [15]   万军. 碳纤维布加固砌体填充墙抗近距离小当量炸药爆炸数值模拟研究 [J]. 工程力学, 2020, 37(S1): 82–90. DOI:
                    10.6052/j.issn.1000-4750.2019.04.S012.
                    WAN J. Numerical simulation of CFRP reinforced concrete masonry wall against small stand-off distance explosive charge [J].
                    Engineering Mechanics, 2020, 37(S1): 82–90. DOI: 10.6052/j.issn.1000-4750.2019.04.S012.
               [16]   LI  Z,  CHEN  L,  FANG  Q,  et  al.  Experimental  and  numerical  study  of  basalt  fiber  reinforced  polymer  strip  strengthened
                    autoclaved aerated concrete masonry walls under vented gas explosions [J]. Engineering Structures, 2017, 152: 901–919. DOI:
                    10.1016/j.engstruct.2017.09.055.
               [17]   彭培, 李展, 张亚栋, 等. 燃气爆炸作用下蒸压加气混凝土砌体墙的加固性能 [J]. 爆炸与冲击, 2020, 40(3): 035101. DOI:
                    10.11883/bzycj-2018-0252.
                    PENG P, LI Z, ZHANG Y D, et al. Performance of retrofitted autoclaved aerated concrete masonry walls subjected to gas
                    explosions [J]. Explosion and Shock Waves, 2020, 40(3): 035101. DOI: 10.11883/bzycj-2018-0252.


                                                         095101-18
   156   157   158   159   160   161   162   163   164   165   166