Page 119 - 《爆炸与冲击》2023年第2期
P. 119
第 43 卷 郝礼楷,等: JPC聚能装药对钢筋混凝土墙毁伤效应的试验与数值模拟研究 第 2 期
D 1 =61.8 cm
D 1 =63.2 cm
D 3 =5.9 cm H 1 =9.2 cm
D 3 =5.9 cm H 1 =9.2 cm
D 4 =4.6 cm H 2 =8.6 cm D 4 =5.5 cm H 2 =10.6 cm Effective plastic strain
2.00
D 2 =64.2 cm D 2 =52.6 cm 1.99
(a) Wall thickness is 60 cm (b) Wall thickness is 70 cm 1.98
1.97
D 1 =62.8 cm 1.96
D 1 =63.4 cm 1.95
1.94
D 3 =5.8 cm H 1 =9.5 cm 1.93
D 3 =5.8 cm H 1 =9.6 cm 1.92
1.91
1.90
D 4 =5.7 cm H 2 =13.8 cm D 4 =5.6 cm H 2 =16.2 cm
D 2 =38.8 cm D 2 =27.6 cm
(c) Wall thickness is 90 cm (d) Wall thickness is 100 cm
图 18 不同厚度钢筋混凝土墙的损伤分布
Fig. 18 Damage distribution of the reinforced concrete wall with different thicknesses
80 20 0.80
D 1 D 3 D 4 H 1
70 D 2 16 H 2 H 3 /δ 0.76
60 12 0.72
D/cm 50 D(H)/cm H 3 /δ
40 8 0.68
30 4 0.64
20 0 0.60
55 65 75 85 95 105 55 65 75 85 95 105
δ/cm δ/cm
图 19 不同厚度钢筋混凝土墙的破坏变化
Fig. 19 Damage of reinforced concrete wall with different thicknesses
4 结 论
设计了一种变壁厚弧锥结合罩的 JPC 聚能装药并进行毁伤大尺寸钢筋混凝土墙试验,研究 JPC 高
速侵彻与爆炸冲击波对钢筋混凝土墙的联合破坏作用,得到以下结论。
(1) 设计的 JPC 聚能装药在比较大的炸高范围内均能够获得稳定、连续的 JPC。在 1.70 倍和 2.50 倍
装药直径的炸高条件下均能够穿透 80 cm(6.67 倍装药直径)厚的大尺寸钢筋混凝土墙,形成直径大于
023302-13