Page 118 - 《中国电力》2026年第3期
P. 118
第 59 卷 第 3 期 Vol. 59, No. 3
2026 年 3 月 ELECTRIC POWER Mar. 2026
引用格式:陶顺, 陈慧琳, 徐永海, 等. 谐波电流允许值分配关键参数取值方法[J]. 中国电力, 2026, 59(3): 114−124.
Citation: TAO Shun, CHEN Huilin, XU Yonghai, et al. Key parameter selection method for allocation of allowable harmonic current values[J].
Electric Power, 2026, 59(3): 114−124.
谐波电流允许值分配关键参数取值方法
陶顺 ,陈慧琳 ,徐永海 ,周胜军 ,肖湘宁 1
1
2
3
1
(1. 华北电力大学 电气与电子工程学院,北京 102206;2. 国网浙江省电力有限公司宁海县供电公司,浙江 宁波
315600;3. 中国电力科学研究院有限公司,北京 100192)
Key parameter selection method for allocation of allowable
harmonic current values
1
3
2
1
TAO Shun , CHEN Huilin , XU Yonghai , ZHOU Shengjun , XIAO Xiangning 1
(1. College of Electrical and Electronic Engineering, North China Electric Power University, Beijing 102206, China; 2. Ninghai County
Power Supply Company, State Grid Zhejiang Electric Power Co., Ltd., Ningbo 315600, China;
3. China Electric Power Research Institute, Beijing 100192, China)
Abstract: Since its promulgation and implementation, GB/T 当前电网发展与现代管理需求。针对新型电力系统中的
14549 has effectively regulated the harmonic issues in power 谐 波 特 征 , 基 于 GB/T 14549 的 谐 波 电 流 允 许 值 分 配 方
grids and ensured the power quality. However, with the 法,分别针对总谐波电流约束指标、供电容量取值方法
和叠加方法,给出关键参数的取值方法,通过案例验证
development of new power systems, the harmonics in power
其合理性与有效性,有效约束了谐波注入,为谐波国家
grids have exhibited new characteristics, making GB/T 14549
标准修订提供参考。
hardly fully adaptable to the current needs of power grid
关键词:GB/T 14549;总谐波电流约束;供电容量;谐波
development and modern management. Therefore, aiming at the
叠加
harmonic characteristics in new power systems, and based on
DOI:10.11930/j.issn.1004-9649.202506024
allocation method for allowable harmonic current values
specified in GB/T 14549, this paper focuses on the constraint
0 引言
index for total harmonic current, the selection method for power
supply capacity, and the superposition method, respectively,
and proposes the selection methods for key parameters. Its 在能源革命和“双碳”目标驱动下,新型电
rationality and effectiveness are validated through the case 力系统的构建促使可再生能源和电力电子设备在
studies, which effectively restricts harmonic injection and 电力系统中的应用快速发展,系统“双高”化趋
provides a reference for the revision of the national harmonic 势显著 [1-9] 。非线性设备接入电网的规模越来越大,
standards. 向电网中注入的谐波电流不断增加,使电网产生
This work is supported by National Natural Science Foundation 额外的谐波损耗,缩短电气设备的使用寿命 [10-19] 。
of China (No.52377101). 为限制谐波注入,中国一直采用 GB/T 14549 国家
Keywords: GB/T 14549; total harmonic current constraint;
标准 [20] (以下简称 GB)。该标准自颁布以来,减
power supply capacity; harmonic superposition
少了因谐波问题引发的电网故障和设备损坏,降
低了设备故障率及维修成本,保证了电能质量。
摘 要:GB/T 14549 自颁布实施以来,有效监督了电网中
的谐波问题,保证了电能质量。随着新型电力系统的发 随着新型电力系统的发展,谐波电流的频谱
展,电网中的谐波呈现新特征,GB/T 14549 难以完全适应 呈现宽频化、高频化的特征。IEC/TR 61000-3-6 [21] 、
G5/5 英 国 工 程 导 则 [22] 和 IEEE Std.519 [23] 均 约 束 了
收稿日期:2025−06−10; 修回日期:2026−01−25。 2~50 次或 2~40 次谐波电压及电压总谐波畸变率,
基金项目:国家自然科学基金资助项目(52377101)。 谐波电流约束频次也随之扩展。除 IEEE Std.519 外,
114