Page 229 - 《摩擦学学报》2021年第6期
P. 229
1014 摩 擦 学 学 报 第 41 卷
这些问题引发出对国内标准的完善和建立适合国人 Durasul highly cross-linked polyethylene acetabular liner for total
行为力学标准的诉求. hip arthroplasty at five years[J]. The Journal of Bone and Joint
Surgery American Volume, 2005, 87(8): 1816–1821. doi: 10.2106/
c. 计算机仿真具有节约时间和成本的优势,简化
jbjs.d.01915.
髋关节的加载(只有轴向力)对步态下的磨损预测结果
[10] Rakow A, Schoon J, Dienelt A, et al. Influence of particulate and
影响不大,因此可以采用ISO等简化后的生物力学曲
dissociated metal-on-metal hip endoprosthesis wear on
线作为计算机仿真研究的输入. 通过对比发现国内数 mesenchymal stromal cells in vivo and in vitro[J]. Biomaterials,
值模拟的预测结果普遍低于体外测试的结果,这说明 2016, 98: 31–40. doi: 10.1016/j.biomaterials.2016.04.023.
仿真模型的可靠性和有效性有待进一步提升. 最后基 [11] Al-Hajjar M, Gremillard L, Begand S, et al. Combined wear and
于骨肌多体动力学和有限元宏微生物力学的系统性 ageing of ceramic-on-ceramic bearings in total hip replacement
生物力学模型可综合研究多因素对摩擦磨损的影响 under edge loading conditions[J]. Journal of the Mechanical
Behavior of Biomedical Materials, 2019, 98: 40–47. doi: 10.1016/
规律,可能是今后磨损预测研究的发展方向.
j.jmbbm.2019.05.011.
参 考 文 献 [12] Messer-Hannemann P, Campbell G M, Morlock M M. Deformation
of acetabular press-fit cups: Influence of design and surgical
[ 1 ] J Kärrholm, C Rogmark, E Nauclér, et al. Annual report 2019[R].
factors[J]. Clinical Biomechanics, 2019, 69: 96–103. doi: 10.1016/
Sweden: The Swedish Hip Arthoplasty Register, 2019.
j.clinbiomech.2019.07.014.
[ 2 ] Cui Wen, Zhang Yali, Wang Zhiqiang, et al. Review of the artificial
[13] Rony L, Pascaretti-Grizon F, Hubert L, et al. Histochemical
hip and knee wear testing standards and simulation testing
identification of wear debris released by alumina-on-alumina hip
machines[J]. Tribology, 2019, 39(2): 248–258 (in Chinese) [崔文,
prostheses in the periprosthetic tissues[J]. Orthopaedics &
张亚丽, 王志强, 等. 人工髋、膝关节磨损测试标准及模拟试验机
Traumatology: Surgery & Research, 2021, 107(1): 102636. doi: 10.
研究进展[J]. 摩擦学学报, 2019, 39(2): 248–258]. doi: 10.16078/
1016/j.otsr.2020.03.027.
j.tribology.2018152.
[14] Qin Yongqiang, Tian Yu, Peng Yuqiang, et al. Research status and
[ 3 ] Wang Chentao, Ge Shirong, Jin Zhongmin, et al. The engineering of
development trend of preparation technology of ceramic particle
orthopedic implants[M]. Shanghai: Shanghai Jiao Tong University
Press, 2016 (in Chinese) [王成焘, 葛世荣, 靳忠民, 等, 骨科植入物 dispersion strengthened copper-matrix composites[J]. Journal of
Alloys and Compounds, 2020, 848: 156475. doi: 10.1016/j.jallcom.
工程学[M]. 上海: 上海交通大学出版社, 2016].
2020.156475.
[ 4 ] Guidelines for technical review of hip prosthesis registration[S].
[15] Wang A, Essner A, Stark C, et al. Comparison of the size and
Beijing: National Medical Product Administration, 2017 (in
Chinese) [髋关节假体系统注册技术审查指导原则[S]. 北京: 食品 morphology of UHMWPE wear debris produced by a hip joint
药品监管总局, 2017]. simulator under serum and water lubricated conditions[J].
[ 5 ] Zhai Bao, Zhang Jiazhen, Aruhan, et al. Application and research Biomaterials, 1996, 17(9): 865–871. doi: 10.1016/0142-9612(96)
progress of in-vitro wear test of hip joint prosthesis[J]. Orthopaedic 83281-9.
Biomechanics Materials and Clinical Study, 2021, 18(1): 74–80 [16] de Ruiter L, Cowie R M, Jennings L M, et al. The effects of cyclic
(in Chinese) [翟豹, 张家振, 阿茹罕, 等. 髋关节假体体外磨损试验 loading and motion on the implant-cement interface and cement
的应用及研究进展[J]. 生物骨科材料与临床研究, 2021, 18(1): mantle of PEEK and cobalt-chromium femoral total knee
74–80]. doi: 10.3969/j.issn.1672-5972.2021.01.018. arthroplasty implants: a preliminary study[J]. Materials, 2020,
[ 6 ] Shah S M. Survival and outcomes of different head sizes in primary 13(15): 3323. doi: 10.3390/ma13153323.
total hip arthroplasty[J]. Journal of Orthopaedics, 2019, 16(6): [17] Bell J, Besong A A, Tipper J L, et al. Influence of gelatin and bovine
A1–A3. doi: 10.1016/j.jor.2019.10.001. serum lubricants on ultra-high molecular weight polyethylene wear
[ 7 ] Singh H, Prakash C, Singh S. Plasma spray deposition of HA-TiO 2 debris generated in in vitro simulations[J]. Proceedings of the
on β-phase Ti-35Nb-7Ta-5Zr alloy for hip stem: characterization of Institution of Mechanical Engineers. Part H, Journal of Engineering
bio-mechanical properties, wettability, and wear resistance[J]. in Medicine, 2000, 214(5): 513–518. doi: 10.1243/09544110015
Journal of Bionic Engineering, 2020, 17(5): 1029–1044. doi: 10.1007/ 35543.
s42235-020-0081-9. [18] Smith S L, Unsworth A. A comparison between gravimetric and
[ 8 ] Smith S L, Unsworth A. An in vitro wear study of alumina-alumina volumetric techniques of wear measurement of UHMWPE
total hip prostheses[J]. Proceedings of the Institution of Mechanical acetabular cups against zirconia and cobalt-chromium-molybdenum
Engineers. Part H, Journal of Engineering in Medicine, 2001, femoral heads in a hip simulator[J]. Proceedings of the Institution of
215(5): 443–446. doi: 10.1243/0954411011536037. Mechanical Engineers. Part H, Journal of Engineering in Medicine,
[ 9 ] Dorr L D, Wan Z, Shahrdar C, et al. Clinical performance of a 1999, 213(6): 475–483. doi: 10.1243/0954411991535086.