Page 98 - 《摩擦学学报》2020年第4期
P. 98
508 摩 擦 学 学 报 第 40 卷
Fe Fe
22 w(C): 7.33% w(C): 6.38%
21 4 Fe w(Si): 2.56% 4 Fe w(Cr): 1.54%
Intensity/a.u. 2 C Si Fe w(Cr): 1.58% Intensity/a.u. 2 C Cr Fe w(Fe): 92.07%
w(Fe): 88.53%
0 Cr Cr 0 Cr
0 5 10 15 0 5 10 15
500 μm
Binding energy/keV Binding energy/keV
(a) SEM micrograph (b) EDS result of region 21 in fig.7 (c) EDS result of region 22 in fig.7
Fig. 7 SEM micrograph and EDS spectra of SiCH lubricated steel balls
图 7 SiCH 润滑钢球磨斑区域的SEM照片和EDS谱图
800
40 000 750 Si2p
700
650
Counts/s 30 000 O1s C1s Counts/s 600
20 000 Fe2p 550
500
450
N1s Si2p 400
10 000
350
0
1 000 800 600 400 200 0 110 108 106 104 102 100 98
Binding energy/eV Binding energy/eV
(a) Full spectrum (b) Si2p
Fig. 8 XPS spectra of elements on worn steel ball
图 8 钢球磨斑区域的XPS光谱图
SRV μm Four Ball μm
8.97 11.84
856.38 856.38
642.28
642.28
428.19
428.19
214.09 −23.92 214.09 −26.17
285.46 570.92 856.38 1 141.84 285.46 570.92 856.38 1 141.84
μm μm
Fig. 9 3D topography of SiCH lubricated ball wear scar
图 9 SiCH润滑钢球磨斑3D形貌图
性能测试前后的红外透过率进行测试,分析其是否有
120
明显变化. 图10为润滑油真空四球试验前后的红外透
100
过率对比,从图10中可以看出,试验前后润滑油在红
Transimittance 60 外波段的透过率无明显变化,均值在60%以上,不会
80
对光学窗口的透过率产生影响.
40
图11为扫描电机寿命验证试验中,两台高、低速
20 After test 电机的试验时间-电机电流曲线图. 其中,高速扫描电
Before test
机已运行6.04×10 r(转),电机电流为12 mA左右;低速
8
0
4 000 3 000 2 000 1 000 电机已运行1.2×10 r,电机电流6.5 mA左右. 按电机目
8
Wave number/cm −1
前已运行6.04×10 r计,单个轴承可供润滑用的润滑油
8
Fig. 10 Comparison of infrared transimittance before and
含量107 mg,可计算得出轴承中的钢球名义润滑寿命
after four ball test of SiCH
图 10 真空四球试验前后SiCH润滑油红外透过率对比 不小于5 644 r/μg.