Page 278 - 《高原气象》2026年第4期
P. 278
高 原 气 象 45 卷
1208
A case study of mesoscale convection triggered by typhoon
peripheral circulation at Mianyang Airport
2
1, 4
Long Yanyan , Chen Guhao , Du Ke 3
(1. Civil Aviation Flight University of China, Guanghan 618307, Sichuan, China;
2. College of Aviation Meteorology, Civil Aviation Flight University of China, Guanghan 618307, Sichuan, China;
3. Mianyang Branch of Civil Aviation Flight University of China, Mianyang 621000, Sichuan, China;
4. China Meteorological Administration Key Laboratory for Aviation Meteorology, Guanghan 618307, Sichuan, China)
Abstract: To reveal the activity patterns of mesoscale convective systems in the northwestern Sichuan Basin un‐
der the influence of typhoon peripheries and to improve meteorological support for airport aviation safety and
low-altitude economic operations, this study analyzes a thunderstorm with heavy rainfall at Mianyang Airport on
July 11, 2025, induced by the outer circulation of Typhoon "Danas". Using multi-source data-including automat‐
ed observations from Mianyang Airport, FY4A satellite imagery, dual-polarization weather radar, and ERA5 re‐
analysis-and applying synoptic diagnostic analysis and short-term nowcasting techniques, this work systematical‐
ly investigates the triggering and development mechanisms of the event, with the aim of supporting aviation safe‐
ty and low-altitude meteorological services. The results indicate that: (1) the event was initiated by the com‐
bined influence of the outer circulation of Typhoon "Danas" (the 4th typhoon of the year) and local circulation
patterns. Key factors included the northward and westward extension of the 500 hPa subtropical high, a trough
over Xinjiang guiding cold air southward, enhanced easterly flow at 700 hPa supplying abundant moisture, and
a surface convergence line that served as a crucial trigger for convection. (2) Pre-event sounding data from Wen‐
jiang Station revealed strong convective potential, with a CAPE of 2547. 5 J·kg , CIN of 0, a K-index of
−1
44. 7 ℃, and significant vertical wind shear. Dynamically, the coupling of upper-level divergence and lower-lev‐
el convergence promoted deep ascent. Thermally and in terms of moisture, high pseudo-equivalent potential tem‐
peratures at 700 hPa and 850 hPa, considerable whole-layer moisture flux, and relative humidity exceeding 90%
at 500 hPa provided ample energy and moisture for convective development. Moist potential vorticity analysis
showed a negative MPV1 center in the lower layers before the event, offering an indicator of convective initia‐
tion. (3) FY4A satellite imagery detected a mesoscale convective cloud cluster northeast of the airport one hour
before the event. The cloud-top brightness temperature reached 215. 78 K prior to thunderstorm onset, corre‐
sponding to the active stage of severe convection. Variations in cloud cluster morphology and cloud-top bright‐
ness temperature helped identify the developmental phase of the convection. (4) Dual-polarization radar ob‐
served a bow echo with 60 dBZ reflectivity 20 km east of the airport before thunderstorm initiation. It moved
-1
westward at 20 km·h and eventually covered the airport, with an echo top reaching 7 km. Radial velocity pat‐
terns, including positive-negative velocity couples, adverse wind regions, and meso- β -scale convergent cy‐
clones and divergence signatures, corresponded to different stages of the convective process. Based on these find‐
ings, a three-tiered forecasting system-covering medium-short-term, short-term, and nowcasting timeframes-
was developed for severe convection at airports. By integrating multi-source data, the system allows accurate pre‐
diction and early warning issuance. It offers a scientific basis for forecasting and warning of airport severe con‐
vection induced by typhoon outer circulations, effectively reducing operational risks and enhancing both airport
efficiency and low-altitude flight safety.
Key words: typhoon; mesoscale convective system; Mianyang Airport; low-altitude economy; diagnostic study

